AGM POWER SYSTEMS
    ONAN HOME STANDBY GENERATORS
    Clean, quiet, and neighborhood friendly, all residential generator models run on either natural gas or propane.

    Why use an residential generator instead of a portable for home standby emergency power? A permanent residential generator set includes many additional features, including a more complex control system, and usually has more power capacity. It also has a weather protective enclosure that is also designed for sound reduction.

    Advantages of using natural gas to fuel your home standby system:
    • Usually unlimited fuel source - refueling not necessary
    • Clean burning
    • Almost always available during power outages
    • No unsightly tank required

    Disadvantages of using natural gas to fuel your home standby system:
    • May be unavailable during natural disasters (earthquakes, etc.)
    • Lower power output (30% less BTU's per unit than gasoline)
    • Larger tanks are not aesthetically pleasing (unsightly)
    • Fuel system plumbing results in higher installation cost
    • Not available in many areas

    Additional options and variances may apply.
    View spec sheet for more details.
    RS 30000
    RS 30000 GGMC (PCC 1301) Spec: A
    Documents
    Spec Sheet a-1493 121 KB
    Operators Manual 961-0117 927 KB
    Generator Ratings
    Hertz 60
    Fuel Natural Gas
    kW 29.0
    kVA Single Phase 36.0
    RPM 1800
    AC Voltage Available 120
    AC Amps 125.0
    Single Phase
    Circuit Breaker 150A 2-pole
    AC Voltage 120
    Voltages-Single Phase Amperes
    120/240 - 125.0/62.5
    Dimensions
    Weight-Dry (Pounds)
    1300.0
    Length (Inches)
    85.3
    Width (Inches)
    30.0
    Height (Inches)
    46.7
    Average Fuel Consumption
    Quarter Load - 25% (Gal/h)
    181.2
    Half Load - 50% (Gal/h)
    259.3
    Three-Quarter Load - 75% (Gal/h)
    338.1
    Full Load
    420.0
    Engine Detail
    Number of Cylinders/Type 4/In-line
    Cooling System Type Liquid
    Oil Capacity (Quarts)
    4.5
    Sound Level 23 Feet in dB(A) Full Load 67
    Comments
      See Spec sheet for footprint dimensions
    RST Automatic Transfer Panel
    60/100/200 Amp transfer panel

    RSZ Automatic Transfer Switch
    100/200 Amp transfer switch